Extended models available: 55kW, 75kW, 90kW, 110kW, 132kW, 160kW. Contact us for specialized ultra heavy-duty industrial and custom elevator specifications.
The 11LIFT 30kW (Drive-30KW-4) is an ultra extreme-duty elevator drive engineered for the most demanding industrial applications including giant freight lifts up to 5000kg, super high-capacity passenger elevators, and specialized heavy industrial transport systems. Featuring dual CPU architecture, closed-loop vector control, and 0 Hz 200% torque output, this industrial-grade VFD delivers 65A output current with 45kVA power capacity, built-in braking, and seamless UPS-backed rescue operation for extreme PMSM gearless motor systems.
| Parameter | Drive-30KW-4 Specification |
|---|---|
| Model Number | Drive-30KW-4 |
| Motor Power | 30 kW |
| Power Capacity | 45 kVA |
| Input Voltage | Three-phase 380V (380-440V range) |
| Input Current | 70 A |
| Output Current | 65 A |
| Control Method | Closed-loop & Open-loop vector |
| Torque Characteristic | 0 Hz 200% torque output |
| Brake Unit | Built-in (standard) |
| Communication | RS485 |
| UPS Operation | Multiple modes supported |
| CPU Architecture | Dual CPU |
| Motor Support | PMSM gearless / Induction motors |
| PG Card | Removable / Field-replaceable |
| Model | Power | Input Current | Output Current | kVA | Application |
|---|---|---|---|---|---|
| Drive-22KW-4 | 22 kW | 52 A | 48 A | 32 | Mega freight / Extreme duty |
| Drive-30KW-4 (This Product) | 30 kW | 70 A | 65 A | 45 | Giant freight / Ultra extreme |
| Drive-37KW-4 | 37 kW | 85 A | 78 A | 60 | Super giant industrial |
| Drive-45KW-4 | 45 kW | 110 A | 100 A | 75 | Colossal freight systems |
Extended models available: 55kW, 75kW, 90kW, 110kW, 132kW, 160kW. Contact us for specialized ultra heavy-duty industrial and custom elevator specifications.
The Drive-30KW-4 provides 35% more output current (65A vs 48A) and 41% more power capacity (45kVA vs 32kVA), enabling substantially heavier loads (5000kg+ vs 3000kg) and higher continuous duty cycles. For giant freight applications with 5000kg+ pallets or continuous heavy industrial cycles, the 30kW ensures thermal stability and motor control precision under extreme stress. The 70A input current requires robust industrial electrical infrastructure—our engineers provide complete electrical specification sheets for installation planning.
The 70A input current at 380V 3-phase requires substantial industrial electrical infrastructure: minimum 80-100A circuit breaker, 35mm² supply cables, and dedicated transformer capacity of 60kVA+ per drive. For facilities with multiple 30kW+ elevators, centralized power distribution with power factor correction is essential. The 45kVA power capacity may require 75kVA+ transformer allocation per drive for safe operation with inrush margins. Our engineers provide complete electrical drawings and coordinate with electrical contractors for installation planning.
Yes. The 65A output current at 30kW supports 5000kg continuous operation with 24/7 duty cycles in heavy industrial applications. The 45kVA power capacity provides substantial thermal headroom for sustained extreme-load operation without derating. The dual CPU architecture ensures precise torque control during continuous 5000kg cycles, while the closed-loop vector control maintains accuracy under thermal stress. For 6000kg+ or specialized continuous industrial applications, consider the 37kW (78A) or 45kW (100A) models.
For giant freight applications with 5000kg loads, we strongly recommend regenerative drive configuration or substantial external braking resistor banks. The built-in 30kW brake handles normal duty cycles, but 5000kg descent generates massive regenerative energy that can overwhelm standard braking in continuous operation. Regenerative drives return energy to the grid, reducing operating costs and eliminating braking resistor heat. Our engineers calculate exact regenerative requirements from your load, speed, height, and cycle frequency to specify optimal braking solutions.
In giant freight applications with 5000kg loads, the dual CPU architecture dedicates one processor to precise torque vectoring during extreme load starts and stops, while the other manages safety circuits and industrial interlocks. This separation prevents control delays that could cause 5000kg load swing or imprecise stopping—critical for industrial safety and precision loading. The anti-rollback function operates independently on the safety CPU, ensuring immediate brake application if anomalies occur during extreme lifting. The 65A output current provides the torque precision necessary for smooth 5000kg acceleration without mechanical stress on drive components.
Our engineering team provides complete drive sizing, electrical infrastructure planning, and integration support for giant freight and ultra extreme-duty industrial elevator projects.
Request 30kW Elevator Drive Quote
📞 Direct technical support: +86 18357241165 (WeChat/WhatsApp)
.product-container { max-width:1200px; margin:0 auto; font-family:’Segoe UI’, Arial, sans-serif; line-height:1.6; color:#333; }
.intro-section h2 { color:#2c3e50; font-size:24px; margin-bottom:15px; }
.features-section h2, .specs-section h2, .applications-section h2, .faq-section h2 { color:#2c3e50; font-size:22px; margin-top:30px; margin-bottom:15px; border-bottom:2px solid #3498db; padding-bottom:10px; }
.features-section h3 { color:#34495e; font-size:16px; margin-top:20px; margin-bottom:10px; }
.features-section ul, .applications-section ul { margin-left:20px; margin-bottom:20px; }
.features-section li, .applications-section li { margin-bottom:8px; }
.faq-section h3 { color:#2c3e50; font-size:16px; margin-top:20px; margin-bottom:8px; }
.faq-section p { margin-bottom:15px; color:#555; }
@media (max-width:768px) {
table { font-size:12px; }
th, td { padding:8px 4px; }
}
| Power Rate | 30kw Closed-loop |
Our engineers will recommend the right configuration for your application.
📞 +86 183 5724 1165 (WeChat / WhatsApp) | ✉️ info@vfdinverters.com