118 Solar Pump Inverter 0.75-110kW MPPT AC DC Hybrid

Price range: $76.00 through $485.00 In Stock
WhatsApp Quote

118 Solar Pump Inverter – MPPT Pumping with AC/DC Hybrid Input

The IDEEI 118 solar pump inverter series drives three-phase or single-phase water pumps directly from solar panels — no batteries required — with AC/DC hybrid input for grid or generator backup. Covering 0.75–110 kW across 220V and 380V models, it brings MPPT solar tracking, dry-run protection and tank-full automation to agricultural irrigation, livestock watering and off-grid water supply.

Key Features of the 118 Solar Pump Inverter

☀️ MPPT Solar Pumping

  • Maximum power point tracking extracts the most from your solar array
  • 0–600 Hz output with V/F and sensorless vector control modes
  • Motor auto-tuning for fast commissioning
  • Recommended solar input sized per model (see tables below)

🔌 AC & DC Hybrid Input

  • Runs directly from the solar DC array — no batteries required
  • Grid or generator AC input as backup / hybrid source
  • Automatic power-off restart when supply returns
  • One drive covers daytime solar and night-time grid pumping

🛡️ Pump Protection Suite

  • Dry-run protection sensor input protects the pump
  • Water-full detection: automatic stop/reset when the tank is full
  • Over-voltage, under-voltage, over-current and overload protection
  • Overheat, input/output phase-loss and earth-fault protection

📡 Control & Monitoring

  • RS485 (Modbus) communication for remote monitoring
  • PID control support for constant-pressure water supply
  • Programmable digital inputs, relay and analog outputs
  • Keypad parameter copy for multi-site deployments

Technical Specifications – 118 Series Model Range

118-D3 Series – 220V Three-Phase Output

Solar DC input: 150–450 VDC (recommended Voc 360–430 V) | Grid AC input: 1PH/3PH 220–240 VAC | Output: 3PH 220–240 VAC

Inverter Power Pump Motor Power Recommended Solar Input Output Current Output Frequency
0.75 kW 0.75 kW 1.0 kW 4 A 0–600 Hz
1.5 kW 1.5 kW 1.95 kW 7 A 0–600 Hz
2.2 kW 2.2 kW 2.86 kW 10 A 0–600 Hz
4 kW 4 kW 5.4 kW 16 A 0–600 Hz
5.5 kW 5.5 kW 8 kW 20 A 0–600 Hz
7.5 kW 7.5 kW 10 kW 30 A 0–600 Hz
11 kW 11 kW 14.3 kW 42 A 0–600 Hz

118-D5 Series – 380V Three-Phase Output

Solar DC input: 250–900 VDC (recommended Voc 620–850 V) | Grid AC input: 3PH 380–480 VAC | Output: 3PH 380–460 VAC

Inverter Power Pump Motor Power Recommended Solar Input Output Current Output Frequency
0.75 kW 0.75 kW 1.0 kW 3 A 0–600 Hz
1.5 kW 1.5 kW 2.2 kW 4 A 0–600 Hz
2.2 kW 2.2 kW 3.3 kW 6 A 0–600 Hz
4 kW 4 kW 5.6 kW 10 A 0–600 Hz
5.5 kW 5.5 kW 8 kW 13 A 0–600 Hz
7.5 kW 7.5 kW 10 kW 17 A 0–600 Hz
11 kW 11 kW 14.3 kW 25 A 0–600 Hz
15 kW 15 kW 19.5 kW 32 A 0–600 Hz
18.5 kW 18.5 kW 23.4 kW 38 A 0–600 Hz
22 kW 22 kW 28.6 kW 45 A 0–600 Hz
30 kW 30 kW 39 kW 60 A 0–600 Hz

118-T3 Series – 380V High-Power Three-Phase

Solar DC input: 350–900 VDC (recommended Voc 620–850 V) | Grid AC input: 3PH 380–480 VAC | Output: 3PH 380–440 VAC

Inverter Power Pump Motor Power Recommended Solar Input Output Current Output Frequency
37 kW 37 kW 48.1 kW 75 A 0–600 Hz
45 kW 45 kW 58.5 kW 90 A 0–600 Hz
55 kW 55 kW 71.5 kW 110 A 0–600 Hz
75 kW 75 kW 97.5 kW 150 A 0–600 Hz
90 kW 90 kW 121.5 kW 180 A 0–600 Hz
110 kW 110 kW 148.5 kW 210 A 0–600 Hz

118-SS2 Series – 220V Single-Phase Output

Solar DC input: 150–450 VDC (recommended Voc 360–430 V) | Grid AC input: 1PH 220–240 VAC | Output: 1PH 220–240 VAC

Inverter Power Pump Motor Power Recommended Solar Input Output Current Output Frequency
0.75 kW 0.75 kW 1.0 kW 7 A 0–600 Hz
1.5 kW 1.5 kW 1.95 kW 10 A 0–600 Hz
2.2 kW 2.2 kW 2.86 kW 16 A 0–600 Hz
4 kW 4 kW 5.4 kW 30 A 0–600 Hz
5.5 kW 5.5 kW 8 kW 42 A 0–600 Hz
7.5 kW 7.5 kW 10 kW 55 A 0–600 Hz
11 kW 11 kW 14.3 kW 80 A 0–600 Hz
15 kW 15 kW 19.5 kW 110 A 0–600 Hz
Control: V/F & sensorless vector | Communication: RS485 (Modbus) | Special I/O: Dry-run sensor input, water-full detection, PID constant-pressure support | Altitude note: derate above 1,000 m

Ideal Applications

  • Agricultural Irrigation: Drip and sprinkler systems for farms, orchards and greenhouses
  • Solar Borehole Pumping: Deep-well and submersible pumps for off-grid water extraction
  • Livestock Watering: Automatic tank filling with water-full detection for ranches
  • Rural & Village Water Supply: Constant-pressure water delivery with PID control
  • Water Transfer & Storage: Daytime solar pumping to storage tanks for night use

Frequently Asked Questions

Does the 118 solar pump inverter require batteries?

No. The 118 series pumps water directly from the solar array without batteries. When sunlight is insufficient, the AC & DC hybrid input lets a grid or generator supply take over, so pumping continues day and night.

Can the 118 series run single-phase pumps?

Yes. The 118-SS2 sub-series outputs single-phase 220–240V for single-phase pumps from 0.75 to 15 kW. The D3, D5 and T3 sub-series drive three-phase pumps — D3 at 220–240V output and D5/T3 at 380V-class output up to 110 kW.

How do I size the solar panels for my pump?

Match two numbers from the specification tables: the recommended solar input power (slightly above pump power) and the array open-circuit voltage (Voc) — 360–430V for 220V models (D3/SS2) and 620–850V for 380V models (D5/T3). Staying inside the recommended Voc window keeps MPPT operation stable.

What protection functions are included?

The 118 series includes a dry-run protection sensor input (stops the pump when the well is dry), water-full detection (automatic stop and reset when the storage tank is full), plus over-voltage, under-voltage, over-current, overload, overheat and phase-loss protection. RS485 Modbus allows remote monitoring of the pumping system.

Is the 118 series in stock and how do I order?

Standard models can be ordered directly at the listed price on this page. For bulk orders, project configurations, or help choosing between the D3 / D5 / T3 / SS2 sub-series, contact our engineering team — we respond within one working day with sizing and a quotation.

Need a Bulk Quote or Model Selection Help?

Standard models can be ordered directly at the listed price. For bulk orders, project configurations, or model selection based on your motor nameplate, our engineering team responds within one working day.

Email: info@vfdinverters.com | WhatsApp/WeChat: +86 183 5724 1165

Power Rate2.2KW、4KW、5.5KW、7.5KW、11KW、15KW
Single/Three PhaseS2、SS2

Need Help Selecting a Model?